TriState HVAC Equipment

Presentations and seminars

Technical seminars and lunch-and-learn sessions for engineers, owners and facility teams. Find a topic and ask us to bring it to your office.

12 presentations

  • Heat rejectionWaterside economizers and free coolingData center cooling

    Adiabatic and hybrid coolers: dry, adiabatic and hybrid heat rejection from the ground up

    How they work, where each one wins, and what to ask for

    A back-to-basics seminar for consulting engineers who have rarely designed adiabatic or hybrid fluid coolers. It starts from the idea that ties the subject together: a dry cooler is limited by the air's dry bulb, an evaporative cooler by its wet bulb, and an adiabatic cooler by the depressed dry bulb its wetted pads produce. It explains how dry, adiabatic and hybrid coolers work and what is inside them; where each wins against a closed-circuit evaporative cooler and against a dry cooler, with the numbers for a humid Mid-Atlantic climate; and how to design them in: design conditions, water use and blowdown, glycol and winter operation, layout and recirculation, structure and sound, controls and switch points, operation without water, the ASHRAE 90.1 heat rejection requirements, green codes, water management and Legionella rules, and performance ratings. It closes with maintenance, common myths, a selection and specification checklist and the key takeaways; the full and product versions add one manufacturer's hybrid and adiabatic lineup, including an adiabatic refrigerant condenser.

    33.75–107.5 min PDH

  • Humidification and humidity control

    Adiabatic humidification in air handling systems

    Psychrometrics, technologies, energy, layout and water treatment

    A technical seminar for consulting engineers and owners of hospitals, universities, laboratories and pharmaceutical buildings on adiabatic humidification: adding moisture to air by evaporating water directly in the airstream. It covers why buildings are humidified and what the standards and the health evidence say; the psychrometrics of isothermal (steam) and adiabatic processes, with a worked winter example for a 10,000 cfm outdoor air unit; how wetted media, high-pressure and compressed-air atomizing, ultrasonic, centrifugal and hybrid humidifiers work and how they compare with steam; an honest look at the benefits, including where the heat of evaporation comes from, how much electrical service electric steam needs and when evaporative cooling helps; how to place and build the humidifier section in an air handler, size the preheat and set the controls and safeties, including the ASHRAE 170 requirements for hospitals; and how to treat the water and manage scaling, mineral dust and Legionella risk. The full presentation and the one-hour overview add one manufacturer's hybrid humidifier, its installation requirements, US hospital installations and matched reverse osmosis systems.

    58.75–89.25 min PDH

  • Data center coolingChilled-water plant design

    Air-cooled magnetic-bearing chillers for data centers

    Oil-free compressors, full-load efficiency and high-ambient design

    Why oil-free magnetic-bearing centrifugal compressors have moved into air-cooled chillers through the data center market, and how a 400 to 600 ton air-cooled design answers what a data center asks of its chillers: full-load kW that sizes wiring, breakers and generators across an array, high ambient and the heat island effect, sound near neighbors, and capacity density. The talk walks through the compressors, flooded evaporator, condenser fan deck and coils, refrigerant economizers, electrical design and options such as integrated waterside economizers, then shows how the chillers serve air-cooled and liquid-cooled white space and what to confirm in a project selection.

    45.25 min

  • Chilled-water plant designHeat rejectionWaterside economizers and free coolingHeat recoveryVariable-speed fan and pump control

    Chilled-water system design and best practices

    Water-cooled plants: chillers, cooling towers, pumps, piping and controls

    A seminar for engineers and contractors who are new to chilled-water plant design. It treats a water-cooled plant as one system of four loops: the coils, chilled-water distribution, the chillers, and condenser water with its cooling towers. It covers where the plant's energy goes and the order in which a designer makes the decisions; how a centrifugal chiller's energy follows its lift, and why a variable-speed chiller needs colder condenser water to deliver its part-load savings; AHRI 550/590 ratings and the plant requirements of ASHRAE 90.1-2025, with the older editions that states in the region still enforce; cooling tower range, approach and fan control, condenser-water pumping and the chiller-plus-tower optimum; pumps, system curves, pipe sizing, the pump room and control valves; constant-flow, primary-secondary and variable primary flow distribution, and low delta-T syndrome; how the piping sets what the controls can do, chiller staging, pump pressure and supply temperature reset, metering and commissioning; an integrated waterside economizer with a plate heat exchanger, with economizer hours for Philadelphia; maintenance; and edge cases such as high condenser temperatures and a small heat-recovery chiller working beside large cooling-only chillers.

    68.5–69 min PDH

  • Data center cooling

    Cooling AI data centers

    Rack density, liquid loops and rack-level cooling, from the chip to the chiller plant

    A presentation for consulting engineers, owners and developers on how AI computing changes data center cooling. It covers how an AI data hall differs from a traditional one: rack density, liquid cooling, fast load swings, power and floor loading, schedule, and existing versus new buildings. It traces GPU and rack power from 2016 through the announced roadmap against typical enterprise racks, and explains in plant-room terms coolant distribution units and the facility and technology cooling loops, warm-water cooling and the ASHRAE liquid cooling classes and what they mean for chillers, and direct-to-chip cold plates and the heat that still goes to air. It then compares the ways to cool a dense rack, shows how sealed rack-level cooling cabinets with their own chilled-water coils and fans work, where they fit and where they do not, and closes with installations and the questions that size an AI cooling project.

    50.5 min

  • Room air distributionZoned heating and cooling

    Designing with active chilled beams

    Induction, primary air, dew point control and rated performance

    A technical seminar for consulting engineers and owners on active chilled beams: ceiling terminals in which ducted primary air, discharged through nozzles, induces room air across a dry water coil. It covers what the beams are and where they fit; why moving heat with water instead of air saves duct space and fan energy, and what the published energy studies do and do not show; how induction, the room air pattern and the split between air-side and water-side cooling work; and how to design a system: zone loads, primary airflow and dew point, condensation control, beam selection and layout, heating, medium-temperature chilled water, piping, zone valves and commissioning. It closes with how beams are designed and tested to ASHRAE Standard 200, what a rating to AHRI Standard 1240 promises and how to specify it, and project examples.

    71.75–73.25 min PDH

  • Humidification and humidity controlHeat recoveryZoned heating and cooling

    Dew point design for dedicated outdoor air systems

    Why DOAS buildings run humid, three laws of design, AHRI 920 and specifying part load

    A technical seminar for consulting engineers, owners and contractors on designing dedicated outdoor air systems (DOAS) that hold indoor humidity at every load. It explains why buildings that pair a DOAS with fan coils, VRF, unit ventilators or chilled beams so often run humid: outdoor air dried only to a neutral dew point, terminal units that follow the thermostat and lose their dehumidification at part load, and units selected at one full-load point and judged by an air-conditioner metric. It sets out three laws of dew point design and works a classroom example from ASHRAE 62.1 ventilation rates to the required supply-air dew point, then covers how dry a coil can practically go, terminal unit sizing, cold or neutral supply air, energy recovery, reheat and the ASHRAE 90.1 limits on it, and dew point control sequences. It compares AHRI 340/360 and IEER with AHRI 920 and its MRC, MRE, ISMRE2 and ISCOP2 metrics, and explains the federal DX-DOAS efficiency standards and AHRI certification. It closes with a Philadelphia weather analysis that shows most dehumidification hours are part-load hours, and with how to schedule and specify part-load performance.

    68–73.5 min PDH

  • Chilled-water plant designHeat recoveryLow-GWP refrigerants and A2L safety

    Modular chillers and air-to-water heat pumps

    Chillers and heat pumps built from modules

    A product-focused tour of one manufacturer's modular line: packaged and modular water-cooled chillers, compressor chillers and condensing units for split systems, modular air-cooled chillers and condensers, and modular air-to-water heat pumps. It starts with why engineers choose modular plants: water-cooled modules sized for a three-foot door, redundancy one module at a time, and capacity and flow that step down with the load. It then walks each line: sizes and arrays, condenser heat recovery to 140 F, split-system arrangements and the ASHRAE 15 rules for A2L refrigerants indoors, liquid-injection compressors and the heat pump operating map, defrost, sizing at the design temperature and heating loop volume. It closes with array controls, factory testing, freeze protection and what to put in a specification. The full session covers every line; focused sessions cover water-cooled equipment, air-cooled equipment and split systems, or air-to-water heat pumps.

    32–59.75 min

  • Hydronic heat transferWaterside economizers and free coolingChilled-water plant design

    Specifying and designing gasketed plate heat exchangers

    Approach temperature, pressure drop and wall shear stress in HVAC service

    A technical seminar for consulting engineers on how gasketed plate-and-frame heat exchangers are built and how the numbers in a specification drive their size, cost and service life. It covers the energy balance, log mean temperature difference and thermal duty, Reynolds number and the Darcy-Weisbach pressure drop, maldistribution, why added fouling factors work against plate exchangers, wall shear stress and part-load operation, port filters and backflush valves for open loops, and certification of liquid-to-liquid heat exchangers to AHRI Standard 400.

    64.25–66.25 min PDH

  • Chilled-water plant designZoned heating and coolingRoom air distributionHeat recoveryHumidification and humidity controlData center coolingHydronic heat transferWaterside economizers and free cooling

    TriState's equipment lines: an overview for engineers and contractors

    Air handling, terminal units, variable refrigerant flow, chillers, heat rejection and specialty equipment

    An introduction to the HVAC equipment lines TriState HVAC Equipment represents, written for consulting engineers and mechanical contractors who are new to TriState. After a short look at the company, its in-house service department and the full line card, it walks through the equipment in three parts. Airside: semi-custom and fully custom air handlers, packaged rooftop and dedicated outdoor air units, fan coils, active chilled beams, unit ventilators, water-source heat pumps, VAV terminals, laboratory room pressure controls, perimeter hydronic heat, and variable refrigerant flow systems with air handler integration and ventilation options. Waterside: water-cooled, air-cooled and modular chillers, air-to-water heat pumps, condensing units, plate heat exchangers, cooling towers, closed-circuit, hybrid and adiabatic coolers, evaporative condensers and condenser-water filtration. Other: variable frequency drives, airflow measurement, pool dehumidifiers, steam and adiabatic humidifiers with water treatment, fan arrays, prefabricated pump houses and central plants, and data center rack cooling and chillers. Each product slide stands on its own: what the equipment is, its current size range and where it fits on hospital, university and commercial projects.

    59.5 min

  • Harmonics and power qualityVariable-speed fan and pump control

    Variable frequency drives and harmonics: how drives work and how to meet IEEE 519 in buildings

    Application, harmonic mitigation, matrix converters and harmonic analysis

    A seminar for consulting engineers, owners and contractors on variable frequency drives in building HVAC and the harmonic current they draw. It explains how a six-pulse PWM drive turns fixed-frequency power into variable speed, what variable speed saves once a system has control head, and why the drive's rectifier draws harmonic current; how harmonics heat equipment, distort voltage, most of all on standby generators, and lower true power factor; how reactors, multipulse drives, passive and active filters, active front ends and matrix converters compare; and how IEEE 519 judges a facility at the point of common coupling, with a worked hospital example, so that a harmonic analysis can size mitigation before it is specified. The full version adds energy-code requirements, multiple motors, enclosures and long motor leads, a step-by-step look at how a matrix converter builds its output and how far its output voltage reaches in theory and in practice, and the 2014 and 2022 revisions of IEEE 519.

    36–113.75 min PDH

  • Low-GWP refrigerants and A2L safetyZoned heating and coolingHeat recovery

    Variable refrigerant flow systems: A2L refrigerant safety, system and piping design, and equipment

    Design and application for engineers and contractors

    A three-part seminar on variable refrigerant flow (VRF) systems for consulting engineers, code reviewers and contractors. Part one explains why new VRF systems are moving to R-32 under EPA's Technology Transitions rule, what the A2L safety class means, how ASHRAE 15, UL 60335-2-40 and the mechanical codes adopted in Pennsylvania, New Jersey, Delaware and New York fit together, and how to apply the ASHRAE 15 method, from room charge limits to detection, shutoff valves and ventilated enclosures. It works the method through an office and a hotel, then covers ceiling voids, machinery rooms, shafts, exit paths, institutional occupancies and installation. Part two covers system and piping design: heat pump and heat recovery, selection, operating range, piping limits and installation practice, how layout drives the refrigerant charge, and ventilation with VRF. Part three surveys one manufacturer's current product family, R-32 except the water-cooled line: outdoor units with their capacity and temperature ranges, indoor units, branch selector and shutoff valve boxes, air handler integration kits for standard and dedicated outdoor air duty, and controls, with dedicated outdoor air units from two other manufacturers that pair with it.

    63.5–185.5 min PDH